Home Inspector
31 important questions on Home Inspector
T/F: A home inspector is required to determine the functional adequacy of in-ground drains.
T/F: A home inspector should determine whether cross-connections are present in the plumbing system.
T/F: A home inspector should disclose any conflicts of interest.
- Higher grades + faster learning
- Never study anything twice
- 100% sure, 100% understanding
T/F: A home inspector should not have an undisclosed financial interest in the home s/he inspects.
T/F: A home inspector should show the client how to operate vinyl single-hung windows.
T/F: A home inspector should test all automatic safety controls.
T/F: A house that has several different styles of crimp rings is a cause for concern.
T/F: A house with integral gutters is more prone to ice damming if it has a steep roof.
T/F: A jalousie window and a louver window are the same thing.
T/F: A joist should be toe-nailed into the sides of a wooden girder if no anchor or ledger strips are used.
T/F: A knob-and-tube wiring system includes a ground wire.
T/F: A lack of building paper creates problems unique to EIFS.
T/F: A laundry tub pump cannot handle human waste.
T/F: A leaking skylight can lead to structural damage.
T/F: A linear-plan house is one room deep.
T/F: A lintel and a header are the same thing.
T/F: A loose or misaligned fan belt can reduce the amount of air flowing past the evaporator coil and decrease an air conditioner's performance.
T/F: A low slope promotes rotting of wood roofs.
T/F: A massed-house plan is two or more rooms deep.
T/F: A metal surface is a common and inexpensive way to cover a large, flat roof.
T/F: A minor roof leak may cause considerable damage before it's noticed.
T/F: A missing grease filter on a kitchen grille is a common problem with heat-recovery ventilators.
T/F: A missing vapor barrier at a duct is a common problem with heat-recovery ventilators.
T/F: A missing, damaged or loose weather hood is a common problem with heat-recovery ventilators.
T/F: A one-pipe steam system can be easily converted into a conventional hot-water system.
T/F: A pilaster is a projection from a wall.
T/F: A poor fuel-to-air mixture can cause incomplete combustion in an oil burner.
T/F: A pressure-reducing valve is an operating control found on a hydronic system.
T/F: A pressure-relief valve may be too small for its boiler.
T/F: A problem with the cabinet is common with high-efficiency boilers.
T/F: A pump is a component in a hot-water distribution system.
The question on the page originate from the summary of the following study material:
- A unique study and practice tool
- Never study anything twice again
- Get the grades you hope for
- 100% sure, 100% understanding